- Home
- Product
Medium Voltage Cable
N2XSY/NA2XSY
1.8/3(3.6) kV
3.6/6(7.2) kV
6/10(12) kV
8.7/15(17.5) kV
12/20(24) kV
18/30(36) kV
IEC 60502-2/SPLN 43-5
- Manufacturing Specification
- Copper/Aluminium conductor, XLPE insulated, Copper wire/ tape screened, PVC/PE sheathed cable
N2XRY/NA2XRY1.8/3(3.6) kV
IEC 60502-1
- Manufacturing Specification
- Copper/Aluminium conductor, XLPE insulated, Aluminium wire armoured, Copper wire/tape screened, PVC/PE sheathed cable
N2XSRY/NA2XSRY
3.6/6(7.2) kV
6/10(12) kV
8.7/15(17.5) kV
12/20(24) kV
18/30(36) kV
IEC 60502-2
- Manufacturing Specification
- Copper/Aluminium conductor, XLPE insulated, Copper wire/tape screened, Aluminium wire armoured, PVC/PE sheathed cable
N2XKY/NA2XKY 1.8/6(3.6) kV
IEC 60502-1
- Manufacturing Specification
- Copper/Aluminium conductor, XLPE insulated, Lead sheathed, PVC/PE sheathed cable
N2XSKY/NA2XSKY
3.6/6(7.2) kV
6/10(12) kV
8.7/15(17.5) kV
12/20(24) kV
18/30(36) kV
IEC 60502-2
- Manufacturing Specification
- Copper/Aluminium conductor, XLPE insulated, Copper wire/tape screened, Lead sheathed, PVC/PE sheathed cable
N2XSY/NA2XSY 1.8/6(3.6) kV
IEC 60502-1
- Manufacturing Specification
- Copper/Aluminium conductor, XLPE insulated, Copper wire/tape screened, PVC/PE sheathed cable
N2XSEY/NA2XSEY
3.6/6(7.2) kV
6/10(12) kV
8.7/15(17.5) kV
12/20(24) kV
18/30(36) kV
IEC 60502-2
- Manufacturing Specification
- Copper/Aluminium conductor, XLPE insulated, with or without water sealing, Copper wire screened, Copper tape screened, PVC/PE sheathed cable
N2XBY/NA2XBY 1.8/6(3.6) kV
IEC 60502-1
- Manufacturing Specification
- Copper/Aluminium conductor, XLPE insulated, Galvanized double steel tape armoured, PVC/PE sheathed cable
N2XSEBY/NA2XSEBY
3.6/6(7.2) kV
6/10(12) kV
8.7/15(17.5) kV
12/20(24) kV
18/30(36) kV
IEC 60502-2
- Manufacturing Specification
- Copper/Aluminium conductor, XLPE insulated, with or without water sealing, Copper tape screened, Galvanized double steel tape armoured, PVC/PE sheathed cable
N2XFGbY/NA2XFGbY 1.8/6(3.6) kV
IEC 60502-1
- Manufacturing Specification
- Copper/Aluminium conductor, XLPE insulated, Galvanized flat steel wire armoured, PVC/PE sheathed cable
N2XSEFGbY/NA2XSEFGbY
3.6/6(7.2) kV
6/10(12) kV
8.7/15(17.5) kV
12/20(24) kV
18/30(36) kV
IEC 60502-2
- Manufacturing Specification
- Copper/Aluminium conductor, XLPE insulated, with or without water sealing, Copper tape screened, Galvanized flat steel wire armoured, PVC/PE sheathed cable
N2XKBY/NA2XKBY 1.8/6(3.6) kV
IEC 60502-1
- Manufacturing Specification
- Copper/Aluminium conductor, XLPE insulated, Lead sheathed, Galvanized double steel tape armoured, PVC/PE sheathed cable
N2XSEKBY/NA2XSEKBY
3.6/6(7.2) kV
6/10(12) kV
8.7/15(17.5) kV
12/20(24) kV
18/30(36) kV
IEC 60502-2
- Manufacturing Specification
- Copper/Aluminium conductor, XLPE insulated, Copper tape screened, Lead sheathed, Galvanized double steel tape armoured, PVC/PE sheathed cable
N2XALCAY/NA2XALCAY1.8/6(3.6) kV
IEC 60502-1
- Manufacturing Specification
- Copper/Aluminium conductor, XLPE insulated, Aluminium corrugated tape armoured, PVC/PE sheathed cable
N2XSEALCAY/NA2XSEALCAY
3.6/6(7.2) kV
6/10(12) kV
8.7/15(17.5) kV
12/20(24) kV
18/30(36) kV
IEC 60502-2
- Manufacturing Specification
- Copper/Aluminium conductor, XLPE insulated, Copper tape screened, Aluminium corrugated tape armoured, PVC/PE sheathed cable
NFA2XSY-T 12/20(24) kV
SPLN 43-5/IEC 60502-2 Aerial twisted cable
- Manufacturing Specification
- Aluminium conductor, XLPE insulated, Copper/wire tape screened, PVC sheathed with stranded galvanized round steel wire insulated messenger
NF2XSY/NFA2XSY 87/150(170) kV
SPLN 43-5/IEC 60502-2
- Manufacturing Specification
- Underground twisted cable Copper/Aluminium conductor, XLPE insulated, with or without water sealing, Copper wire/tape screened, PVC sheathed cable